Also Known as:
Object Type: Open Clusters and Nebula
Constellation: Cassiopeia
Distance from Earth: 5,000 light years (NGC 7788) & 10,800 light years (NGC 7790), 12,000 light years (Sh2-168)
Apparent Magnitude: 9.4 (NGC 7788) & 8.5 (NGC 7790)
Coordinates: RA 23H 56M 0S DEC 61 deg 24 min 00 sec (NGC 7788) ... RA 23H 58M 24.2S DEC 61 deg 12 min 30 sec (NGC 7790)
Actual Size: 5 light years in diameter (NGC 7788) ... 15 light years in diameter (NGC 7790)
Apparent Dimensions: 2.4 arc minutes (NGC 7788) .. 7.4 arc-minutes (NGC 7790)
--------------------------------------------------------------------------
Environmental Data
Date: September 15, 2024     Start Time: 8:21PM    End Time: 2:51AM     SQM: 18.66
Moon Age: 12.5 days     Moonset: 2:54AM     Moon Illumination: 94.0%
Temperature: 61 degrees F    Humidity: 80%    Dew Point: 55 degrees F
Location: Westport, Massachusetts 02790    Sky Condition: Clear but bright Moon
Comment: Moon was very bright all night
--------------------------------------------------------------------------
Imaging Scope Data
Mount: iOptron CEM120     Camera: ZWO ASI2600 OSC     Focuser: Optec DirectSync SVX30
Telescope: Stellarvue SV90 refractor   Focal Length: 504mm
Focal Reducer/Field Flattener: 0.8    Filter: IDAS NB-1
Rotator: Pegasus Falcon rotator     Power Control: Pegasus Ultimate Powerbox V2     Dew Heater: Kendrick dew strip
Imaging Software
Mount: iOptron Commander     Focuser: Optec FocusLynx Commander
Imaging: Sequence Generator Pro     Platesolve: ASTAP     Rotator/Control: Pegasus Unity Platform
Imaging Status
Imaging Software: Sequence Generated     Focus HFR: 1.47     Platesolve: Good on 3rd attempt    
--------------------------------------------------------------------------
Guide Scope Data
Telescope: Stellarvue SVX130 refractor    Camera: ZWO ASI290 Focuser: Optec DirectSync SV35
Dew Heater: Kendrick dew strip    Software: PHD2    Exposure: 2 sec    Binning: 1x1    Tracking Result: 0.6 arc-seconds RMS
--------------------------------------------------------------------------
Images Taken
Number of light frames: 91        Duration: 4 minutes        Gain: 100        
Camera Temperature: 0 degrees C        Binning: 1x1        F-Stop: 5.6        
Total Integration Time: 6.07 hours
--------------------------------------------------------------------------
Number of flat frames: 50        Duration: 0.15 seconds        Gain: 100        
Camera Temperature: 0 degrees C        Binning: 1x1        F-Stop: 5.6        
Flat Field Illumination: All-Pro 'Spike-a-Flat Field standard' illuminated panel
--------------------------------------------------------------------------
Number of Dark frames: 50 (from library)       Duration: 2 minutes        Gain: 100        
Camera Temperature: 0 degrees C        Binning: 1x1        F-Stop: 5.6        
--------------------------------------------------------------------------
Number of Bias frames: 50 (from library)        Duration: 0.001 seconds        Gain: 100        
Camera Temperature: 0 degrees C        Binning: 1x1        F-Stop: 5.6        
--------------------------------------------------------------------------
Imaging Processing
Imaging Processing Software: PixInsight
Processes utilized: Linear - calibration/integration: Flats ImageCalibration with Master Bias, Flat ImageIntegration, Images ImageCalibration with Flat Master & Dark Master, Debayer, SubFrameSelector, StarAlign, ImageIntegration
Linear - Background extraction, Color correction, deconvolution, noise reduction: DynamicBackgroundExtraction, ImageSolve, SpectroPhotometricColorCalibration, BlurXTerminator, NoiseXTerminator
Non-Linear: GeneralizedHyperbolicStretch script, CurvesTransformation, HistogramTransformation
--------------------------------------------------------------------------
Notes:
Click Below Image for Full Size:
Click to Return to Home Page